Silencers beside a heat recovery unit: where do they help most?

A silencer is often remembered only after the heat recovery unit is installed and a hum is audible in the bedroom. The best time to provide for it, however, is during design. Not every sound comes from the fan itself, and not every problem is solved by the same duct insert. First establish the sound path: duct-borne sound, local airflow noise, casing radiation or vibration transmitted through the structure. The solution depends on that distinction.

Not all sounds travel in the same way

Fan sound can travel through the duct network into rooms. Another source is excessive velocity or an unsuitable component at the air terminal. Vibration can be transmitted through fixings, while sound between rooms can pass along their connecting route. These effects can occur together. Asking 'which silencer should I buy?' is therefore premature if the cause is unknown.

The Lindab sound-theory document discusses sources and silencer selection. In practice, frequency bands and the particular component's attenuation matter alongside an overall decibel figure. The advertising phrase 'reduces noise' alone does not say whether the component will address the particular problem being heard.

Location must relate to the sound path

A silencer beside the unit can reduce fan sound on the relevant duct side. However, it does not in itself eliminate sound generated further downstream at an unsuitable air valve. If the issue is sound radiated by the casing into the technical room, a component inserted in a duct may have limited effect. The identified path must be addressed specifically.

The Komfovent installation manual illustrates why appliance installation and system components are planned together. The location must allow correct connection, isolation and maintenance of components. If everything is squeezed into a tight cupboard, there may later be neither space for the required silencer nor safe access. This risk is worth assessing before purchase.

A silencer also has resistance

The additional component is included in the pressure-loss assessment. Diameter must not be reduced without checking merely because a smaller part fits between the pipes. Both airflow and noise can change. The particular product must be selected for the required air quantity, and the system operating point must remain justified.

The PNNL air-movement explanation helps explain the significance of resistance. Reduced sound caused by throttled airflow is not the same as a properly quietened, functioning system. After correction, check that the intended air quantity remains. Otherwise, the owner gets a quieter but less well-ventilated room.

Illustrative example: humming in only one room

Suppose the heat recovery unit is not very audible in the technical room, but whistling comes from one bedroom. The other rooms do not have that sound. This is a signal to check the particular branch, air valve setting and flow, not automatically replace the entire unit. Local sound may have a different origin from general fan hum.

A specialist checks the operating mode, measures airflow and assesses the route. If an unsuitable local component or adjustment is the cause, that section is corrected. If duct-borne sound is confirmed, suitable attenuation is selected. This sequence avoids an expensive component installed in a convenient but acoustically unhelpful location.

Vibration is a separate issue

Rigid fixing to a lightweight structure can transmit vibration. The base, fixing detail and manufacturer-specified connections must then be assessed. Improvising with soft materials placed underneath may be unsuitable for load, safety or stability. The installation solution must be justified for the particular unit and structure.

Do not loosen brackets on your own initiative or suspend the unit differently from its intended arrangement. A quieter short test does not mean a safe long-term fixing. If vibration appeared suddenly, it may indicate a maintenance issue or fault. Diagnostics are needed first in that case, not extra finishing panels to conceal the sound.

Sound between rooms

If conversations from another room are audible through ducts, the problem is not only the fan. Assess the branch layout and sound transmitted between rooms. Distribution-box or additional attenuation solutions must be selected for the system. A branch must not be blocked independently merely for privacy.

It is worth telling the designer about this need in advance. The arrangement of bedrooms, studies and other sensitive rooms matters. Even good acoustics of the main unit do not establish how sound will pass between two particular rooms. The complete layout is needed, not just a product catalogue.

How to check the result

The comparison must use the same ventilation mode and similar conditions. If the unit ran quickly before the work and was left at minimum afterwards, the sound difference does not show the silencer's benefit alone. Record the operating point and actual airflows. If acoustic measurement is carried out, the method and background noise must be clear.

It is useful for the owner to distinguish daytime and night-time expectations. A quiet room at night makes sounds audible that are not heard in a showroom or during the day. Discuss acceptance conditions before the work. Do not establish one universal acceptable number from a phone app without assessing its measurement limits and applicable requirements.

Separate diagnostics and installation in the proposal

If the sound's cause is not yet established, it is sensible to divide the task into an inspection and work selected according to its findings. There will then be no need to buy a component in advance merely because it is called a silencer. The inspection conclusion must explain which path was confirmed and what could not be checked. If a particular component is proposed, ask for attenuation and resistance data and its intended installation location.

Also address maintenance. A component must not be planned so that its condition later becomes completely inaccessible or requires dismantling a large area of finish. The quietness solution must remain maintainable, like the rest of the ventilation system. Discuss this together with the final ceiling and cupboard arrangement.

What to include in an enquiry

State the appliance model, mode, sound location and when it appeared. If possible, include a route layout and photographs. A short recording may help describe the sound, but does not replace professional measurement or inspection. Read more about system selection here, and describe the situation using the contact form. The aim is an appropriate air quantity with sound managed on a justified basis, not merely a muffled fan.

Information sources

You can read the explanation without leaving this page. The original document opens only when you choose its link.

How the source is used in this article

Lindab: sound theory and silencer selection

The Lindab sound-theory document discusses sources and silencer selection. In practice, frequency bands and the particular component's attenuation matter alongside an overall decibel figure. The advertising phrase 'reduces noise' alone does not say whether the component will address the particular problem being heard.

Source checked on 2026-10-26. This is the article's explanation, not a copy of the original document.

Original source

Open original source ↗

How the source is used in this article

Komfovent DOMEKT: installation and maintenance instructions

The Komfovent installation manual illustrates why appliance installation and system components are planned together. The location must allow correct connection, isolation and maintenance of components. If everything is squeezed into a tight cupboard, there may later be neither space for the required silencer nor safe access. This risk is worth assessing before purchase.

Source checked on 2026-10-26. This is the article's explanation, not a copy of the original document.

Original source

Open original source ↗

How the source is used in this article

PNNL: the physics of building air movement

The PNNL air-movement explanation helps explain the significance of resistance. Reduced sound caused by throttled airflow is not the same as a properly quietened, functioning system. After correction, check that the intended air quantity remains. Otherwise, the owner gets a quieter but less well-ventilated room.

Source checked on 2026-10-26. This is the article's explanation, not a copy of the original document.

Original source

Open original source ↗